ANSWER The mold in the crawl space is caused partly by that roof leak, which overpowered the venting system, but I think inadequate ventilation is more the cause. Your ridge vent is adequate, but the 8-inch-long soffit vents are inadequate, venting only half the space between rafters. To prevent the mold from returning, get rid of the perforated aluminum, which is blocking air flow, and replace the short vents with a continuous louvered strip 2 inches wide and the full length of the soffit. Return to the "Crusader Q&A Topics" page! If